Care Guide
1. Cleaning Condenser
Clean the condenser regularly at least every 6 months.
Condenser is located on the ambient air intake side of the cooling unit.
Use a condenser brush or a vacuum cleaner with an extended attachment to
clean the condenser.
2. Removing Condensate
Remove the excessive condensate if it is accumulated on the cooling unit in high
humidity conditions.
3. Removing Unit
When you remove the cooling unit, beware water may come out of the unit.
4. Installing Drain Line
WM-3500~8500HZD units are equipped with an additional drain fitting. In case of
extreme humidity there is a drain line needed, remove the drain plug on the
bottom left at the rear, then remove the connection plug and fit a 0.375” OD drain
tube into the drain connection. Install the cooling unit with the front higher than
the rear.